IETF BibXML

Viewing source data: IEEE_1573-2021_REDLINE indexed from relaton-data-ieee
docid.id IEEE 1573-2021 Redline
docid.type IEEE
docid.primary True
docid#2.id IEEE 1573™-2021 Redline
docid#2.type IEEE
docid#2.primary True
docid#2.scope trademark
docid#3.id 978-1-5044-9195-2
docid#3.type ISBN
docnumber IEEE 1573-2021 Redline
language en
type standard
script Latn
date.value May 9, 2022
date.type created
date#2.value Nov. 18, 2022
date#2.type published
date#3.value Dec. 8, 2021
date#3.type issued
relation.type updates
relation.bibitem.formattedref.content IEEE 1573-2003
relation.bibitem.formattedref.format text/plain
relation.bibitem.docid.id IEEE 1573-2003
relation.bibitem.docid.type IEEE
relation.bibitem.docid.primary True
relation.bibitem.id IEEE1573-2003
relation.description.content revises
relation.description.format text/plain
relation.description.script Latn
relation.description.language en
title.content IEEE Recommended Practice for Electronic Power Subsystems: Parameters, Interfaces, Elements, and Performance
title.format text/plain
title.type title-main
title#2.content IEEE Recommended Practice for Electronic Power Subsystems: Parameters, Interfaces, Elements, and Performance - Redline
title#2.format text/plain
title#2.type main
abstract.content A technical basis for implementation of electronic power subsystems is provided in this recommended practice. It is intended for electronic systems engineers and integrators, electronic power subsystem designers and integrators, as well as for power element manufacturers and suppliers. System-level issues in element or subsystem integration, adaptation, and accommodation are addressed, and system interface parameters, test methods, and test conditions are defined. Ac-dc, dc-ac, and dc-dc electronic power subsystems are discussed. The range of electronic power subsystems includes those with dc, single-phase, and three-phase inputs, having power levels from a fraction of a watt up to 20 kW. The voltage range is 600 V and below at a frequency or frequencies of dc 1 kHz. Internal operating frequencies within elements or subsystems may be much higher than 1 kHz. This recommended practice may be used outside the range where applicable. IEEE Std 1515-2000 is built on and supplemented in this document.
abstract.format text/plain
abstract.script Latn
abstract.language en
revdate Nov. 18, 2022
contributor.role.type publisher
contributor.organization.name.content Institute of Electrical and Electronics Engineers
contributor.organization.contact.address.city New York
contributor.organization.contact.address.country USA
contributor.organization.url http://www.ieee.org
contributor.organization.abbreviation.content IEEE
keyword IEEE Standards
keyword#2 Power systems
keyword#3 Power electronics
keyword#4 Voltage control
keyword#5 electronic power subsystems
keyword#6 IEEE 1573
keyword#7 power electronics
id IEEE1573-2021Redline
docstatus.stage.value Active
ics.code 31.020
ics.text Electronic components in general
editorialgroup.committee Standards Committee of the IEEE Power Electronics Society